Hired-hand Super-Savers (Forced Air Heaters) XL: Blower Motor User Manual

Browse online or download User Manual for Radiators Hired-hand Super-Savers (Forced Air Heaters) XL: Blower Motor. Hired-Hand Super-Savers (Forced Air Heaters) XL: Blower Motor Insulation Installation User Manual [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Blower Motor Insulation Installation
Super Saver XL Heaters
Part No. 4801-2980
Tools Required
5/16 inch Wrench 1/4 inch Nut-driver
1/8 inch Allen Wrench
Directions
Study the drawing below before proceeding.
Blower Housing
Setscrew
Blower Wheel
Motor Mounting Plate
Motor
Insulation
Figure 1
Figure 1 above shows the components in the blower motor assembly. Make sure that each component
goes on the shaft in the order shown.
1. Disconnect electrical power to the heater and shut off gas supply.
2. Open the Side-Swinging door and find the motor.
3. Disconnect the wires to the motor.
4. Make match marks on the motor mounting plate and the blower housing. This is to make sure the
assembly can be replaced in the same alignment as it is currently installed.
5. Remove the blower motor assembly by removing the (ten) 1/4 inch screws from the motor mounting
plate. (Note: For easier removal of blower assembly, leave one screw on the top row for last.)
6. Remove blower wheel using the 1/8 inch allen wrench.
Page view 0
1 2

Summary of Contents

Page 1 - Super Saver XL Heaters

Blower Motor Insulation InstallationSuper Saver XL HeatersPart No. 4801-2980Tools Required5/16 inch Wrench 1/4 inch Nut-driver1/8 inch Allen WrenchDir

Page 2

7. Place insulation on shaft. There is a pre-cut cut hole in the center of the insulation for the shaft. Makesure that the silver side of the insulati

Comments to this Manuals