Gas Valve Replacement
Tools required:
Adjustable Wrench Pipe Sealant
Pipe Wrench Gas Leak Testing Solution
1/4 in. Nut Driver
Directions
1) Turn toggle switch that is located on the control panel to the OFF position.
2) Unplug heater power cord from it’s receptacle.
3) Turn ball valve to the closed position.
4) Shut OFF gas supply up stream of the heater’s gas hose.
5) Disconnect gas hose from the ball valve.
6) Attach pipe wrench to 3/4 in. pipe nipple that extends from the gas valve to the ball
valve, turn counter clockwise removing the 3/4 in. pipe nipple and the ball valve.
7) Remove the bolt located directly beneath the brass orifice, from the under side of
the heater bottom.
8) Disconnect the red and green wires going to the gas valve.
9) Remove the gas valve from the heater.
10) Remove orifice and 1/4 in. pipe nipple assembly from the original gas valve.
11) Apply pipe sealant to threads, and reinstall on the replacement gas valve.
Note: The direction of flow arrow on the bottom side of the gas valve should point in the
direction of the brass orifice.
Note: Steps 12-14 are to be performed only if you presently have a White-Rogers
gas valve. If you have a Honeywell gas valve go to step 15.
12) Remove the gas valve bracket from the heater bottom.
13) Cut template along dotted line, insert into the gas valve’s old position (with arrow
pointing towards ball valve opening), and mark designated opening.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Gas Valve Replacement

HIRED-HAND, INC. · 1733 Co Rd 68 · Bremen, AL 35033 ·-Phone 1-800-642-0123 · Fax 205-287-2000Manual Part No. 4801-0057 Page 1 of 4Gas Valve Replacem

Page 2

HIRED-HAND, INC. · 1733 Co Rd 68 · Bremen, AL 35033 ·-Phone 1-800-642-0123 · Fax 205-287-2000Manual Part No. 4801-0057 Page 2 of 414) Drill designat

Page 3 - Gas Valve

HIRED-HAND, INC. · 1733 Co Rd 68 · Bremen, AL 35033 ·-Phone 1-800-642-0123 · Fax 205-287-2000Manual Part No. 4801-0057 Page 3 of 4g) To adjust the m

Page 4 - Ball Valve

HIRED-HAND, INC. · 1733 Co Rd 68 · Bremen, AL 35033 ·-Phone 1-800-642-0123 · Fax 205-287-2000Manual Part No. 4801-0057 Page 4 of 4BurnerOrificeGas V

Comments to this Manuals

No comments